v5.0.6 - Changes in html pages to accommodate smartnotebook's move to new website.
v5.0.5 - The init procedure now unsets the "mySpectra" array variable whenever the user changes experiments (Init Screen 2). This fixes a bug regarding the use of the "Back" button in Init Screen 3 (and perhaps other bugs associated with an experiment change).
v5.0.5 - Fix bug regarding the update of ppm.out output file whenever snb is started with a new chains file.
v5.0.5 - Corrected error when changing maximum value in the vertical scale window.
v5.0.5 - Added "Latest News" to Help menu, removed "About Smartnotebook" from File menu, and changed "Smartnotebook Home" to "v5.x Manual". This more clearly indicates sources of documentation. Updated associated documentation.
v5.0.5 - Corrected the hnco-yves example which is missing the par files and updated documentation (ex-hnca.html) mentioning the byteorder parameter for linux machines. Correct html errors in ex-orb.html and faq.html. Update docs/README.
v5.0.4 - Initialization procedure now asks for user's par files if he/she has them. This was an important fix because without the par files nmrview cannot properly draw spectra. The par files need to exist in the current directory.
v5.0.4 - Remove extraneous tiff files from documentation. Edit documentation and replace screen snapshots to reflect above changes. Update devtools documentation so that it is current.
v5.0.4 - Better checking of values set in the "snb.init" file. This fixes problems when I try to fabricate snb environments for users in the test cases. For example, try the web browser in the "hsqc-basic" test case.
v5.0.4 - Minor gui adjustments. Background for insertion cursor set to white, easier to see. Main snb menubar items set closer together. Added X-padding around fit window. Added "help" button with documentation to Screen 4 of the initialization procedure.
v5.0.4 - Print out reasonable error when the snb does not know what connectivity the user has selected to "Add to chain". The old error was a variable not existing with a "-1" array index.
v5.0.3 - Problems with writing out the ppm.out file should be fixed. If you have ever had snb read in a ppm.out file and started assigning and un-assigning chains, the software sometimes got confused with what were the correct shifts. Now the algorithm is clear. Note that any assignments made in smartnotebook take precedence over those read in (if such a conflict should arise).
v5.0.3 - The making of the v5.x release broke the conversion of nmrDraw format "*.tab" peakpick files to ".xpk" format within initialization procedure. Fixed this.
v5.0.3 - Simplify initialization procedure for creating/inputting the shift constraints file. This was done by having separate windows for the input sequence file and the shifts file. It is much easier to follow now. The number of initialization windows changes from 5 to 6. The startup example documentation was re-written.
v5.0.3 - As a result of the above, this fixes the bug where if you return from "orb" unsuccessful, you are now placed in the proper window state (which is screen 4 of 6).
v5.0.3 - Simplify connectivity file input. The "import connectivity files" item is added to the File menu. Documentation is provided in the example cases.
v5.0.3 - Minor Corrections to documentation.
This file last updated: Questions to: bionmrwebmaster@biochem.ualberta.ca