<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="http://www.bionmr.ualberta.ca/bdswiki/skins/common/feed.css?303"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>http://www.bionmr.ualberta.ca/bdswiki/index.php?action=history&amp;feed=atom&amp;title=Running_NMR_spectrum</id>
		<title>Running NMR spectrum - Revision history</title>
		<link rel="self" type="application/atom+xml" href="http://www.bionmr.ualberta.ca/bdswiki/index.php?action=history&amp;feed=atom&amp;title=Running_NMR_spectrum"/>
		<link rel="alternate" type="text/html" href="http://www.bionmr.ualberta.ca/bdswiki/index.php?title=Running_NMR_spectrum&amp;action=history"/>
		<updated>2026-04-05T00:57:59Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.20.2</generator>

	<entry>
		<id>http://www.bionmr.ualberta.ca/bdswiki/index.php?title=Running_NMR_spectrum&amp;diff=73&amp;oldid=prev</id>
		<title>Wikiroot: Created page with &quot;Typical parameters for nmr600:  Spectra were acquired on a 600-MHz Inova NMR spectrometer at 25 °C using the tn noesy pulse sequence (circa Vnmr 6.1B software, Varian Inc).  ...&quot;</title>
		<link rel="alternate" type="text/html" href="http://www.bionmr.ualberta.ca/bdswiki/index.php?title=Running_NMR_spectrum&amp;diff=73&amp;oldid=prev"/>
				<updated>2012-12-18T21:51:21Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;Typical parameters for nmr600:  Spectra were acquired on a 600-MHz Inova NMR spectrometer at 25 °C using the tn noesy pulse sequence (circa Vnmr 6.1B software, Varian Inc).  ...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;Typical parameters for nmr600:&lt;br /&gt;
&lt;br /&gt;
Spectra were acquired on a 600-MHz Inova NMR spectrometer at 25 °C using the tn noesy pulse sequence (circa Vnmr 6.1B software, Varian Inc). &lt;br /&gt;
&lt;br /&gt;
Spectra had an acquisition time of 4 s, a preacquisition delay of 1 s, a mixing time of 0.1 s, a sweep width of 7200 Hz, and 256 transients.&lt;br /&gt;
&lt;br /&gt;
 {Saude, E. J., Slupsky, C. M., and Sykes, B. D. (2006) Metabolomics 2, 113-123}&lt;br /&gt;
&lt;br /&gt;
   ACQUISITION            SAMPLE            PROCESSING        2D PROCESSING&lt;br /&gt;
 sfrq       599.856  date   Sep 29 2010  lb        not used  lb1       not used&lt;br /&gt;
 tn              H1  solvent        D2O  sb        not used  sb1         -0.085&lt;br /&gt;
 at           4.000  temp          30.0  gf        not used  sbs1        -0.085&lt;br /&gt;
 np           67184      DECOUPLING      proc            ft  gf1       not used&lt;br /&gt;
 sw          8398.1  dn                  fn          262144  fn1           2048&lt;br /&gt;
 bs               8  dof        -3326.9  ssfilter  not used        FLAGS&lt;br /&gt;
 ss               2  dm            nnnn  ssorder   not used  dp               y&lt;br /&gt;
 tpwr            58  dmm           cccp  ssntaps        200  C13refoc         n&lt;br /&gt;
 pw             8.8  dpwr            48  sslsfrq   not used  N15refoc         n&lt;br /&gt;
 d1           0.010  homo             n      GRADIENTS       CNrefoc          n&lt;br /&gt;
 d2               0    2D ACQUISITION    gt1         0.0030      SATURATION&lt;br /&gt;
 mix          0.100  sw1         8398.1  gzlvl1        5000  mfsat            n&lt;br /&gt;
 tof         -219.5  ni               1  gt2         0.0050  sspul            n&lt;br /&gt;
 nt             256  phase            1  gzlvl2        7500  satmode       ynyn&lt;br /&gt;
 ct             256                                          satpwr           6&lt;br /&gt;
                                                             satdly       0.990&lt;br /&gt;
                                                             scuba            n&lt;/div&gt;</summary>
		<author><name>Wikiroot</name></author>	</entry>

	</feed>